Measurement Accuracy | |
Voltage DC | 30.000 V: 0.02% + 2 counts (upper display) 10.000 V: 0.02% + 2 counts (lower display) 90.00 mV: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA: 0.02% + 2 counts |
Resistance | 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) |
Frequency | 2.0 to 1000.0 CPM: 0.05% + 1 count 1.0 to 1100.0 Hz: 0.05% + 1 count 1.00 to 10.00 kHz: 0.05% + 1 count Sensitivity: 1 V peak-to-peak-minimum |
Pressure | Accuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure. |
Source Accuracy | |
Voltage DC | 100.00 mV: 0.02% + 2 counts 10.000 V: 0.02% + 2 counts -10.00 to 75.00 mV: 0.025% + 1 count (via TC connector) |
Current DC | 24.000 mA (source): 0.02% + 2 counts 24.000 mA (simulate): 0.02% + 2 counts |
Resistance | 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) 401 to 1500 Ω: 0.5 Ω (excitation current 0.05 to 0.8 mA) 1500 to 3200 Ω: 1 Ω (excitation current 0.05 to 0.4 mA) |
Frequency | 2.0 to 1000.0 CPM: 0.05% 1.0 to 1100.0 Hz: 0.05% 1.00 to 10.00 kHz: 0.25% Waveform: 5 V p-p squarewave, -0.1 V offset |
RTDs and Thermocouples | |
Measure Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 35.24°F (1.8°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Source Accuracy | NI-120: 32.36°F (0.2°C) PT-100 (385): 32.6°F (0.33°C) PT-100 (393): 32.54°F (0.3°C) PT-100 (JIS): 32.54°F (0.3°C) PT-200 (385): 32.36°F (0.2°C) PT-500 (385): 32.54°F (0.3°C) PT-1000 (385): 32.36°F (0.2°C) Resolution: 0.1°C Accuracy stated for 4-wire measurement. J: 33.26°F (0.7°C) K: 33.44°F (0.8°C) T: 33.44°F (0.8°C) E: 33.26°F (0.7°C) R: 34.52°F (1.4°C) S: 34.7°F (1.5°C) B: 34.52°F (1.4°C) L: 33.26°F (0.7°C) U: 33.35°F (0.75°C) N: 33.62°F (0.9°C) Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C XK: 33.08°F (0.6°C) BP: 34.16°F (1.2°C) |
Functions Specifications | |
Ramp Functions | Source functions: Voltage, current, resistance, frequency, temperature Ramps: Slow ramp, Fast ramp, 25% step-ramp |
Loop Power Function | Voltage: 12 V Accuracy: 10% Maximum current: 22 mA, short circuit protected |
Step Functions | Source functions: Voltage, current, resistance, frequency, temperature Steps: 25% of range, 100% of range |
Mechanical and General Specifications | |
Batteries | 4 x AA alkaline batteries |
Battery Replacement | Separate battery compartment, accessible without breaking calibration seal |
Side Port Connections | Pressure module connector |
Dimensions | 5.188 x 9.291 x 2.402" (130 x 236 x 61 mm) |
Weight | 1.874 lbs (0.85 kg) |